Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 02/06/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOSE BIB S.E. CORNER 2) SEAL WATER CLOSETS AT BASE (4) 3) PROVIDE CERTS |
|
| 01/31/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE GRADING 2) INTERIOR 3) SEAL WATER CLOSETS AT FLOOR (4) 4) PROVIDE STUCCO AND INSULATION CERTS |
|
| 01/29/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GRADING NOT COMPLETE AND SIDE WALK DRAINAGE STILL NOT MET 2) VTR STACKS ON ROOF NOT PAINTED 3) UNIT #1 DISHWASHER HOSE NEEDS TO BE CLAMPED TO BACK OF CABINET AND CLAMPED TO NIPPLE AT TRAP 4) ELECTRICAL COVER PLATE UNDER SINK MISSING 5) NEED ANTI-SIPHON DEVICE ON HOSE BIBS |
|
| 01/11/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE GRADING TO SLOPE FROM HOUSE 2) NO RANGE ANTI-TIP 3) SIDEWALK SOUTH SIDE PREVENTS PROPER DRAINAGE |