Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03160

Parcel: 13510150R

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM03160

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/17/2005 FRAMING Approved IVRS - Inspection :*
08/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BUILD PER PLAN OR REVISE PLAN. SEE REJECTION NOTES DATED 7/26/05
07/28/2005 FRAMING Partial Approval IVRS - Inspection :*
P- FITNESS ROOM WALL
2. PLEASE COMPLETE ALL WORK. THIS JOB IS NOT LARGE ENOUGH TO CALL IN PARTIALS.
07/26/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLANS CALL FOR SOLID 2 X 4 EDGE AT ALL OPENINGS
2) REF: ALL DETAILS PP A-2