Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM03126
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/31/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. VACUUM BREAKER HOSE BIBBS 2. SEAL B-VENT LID 3. HARD PIPE TPR VALVE 4. LABEL CIRCUITS MAIN SERVICE PANEL 5. PAINT ROOF VENTS ABS 6. LIGHT FIXTURE CLOSET WITHIN 12' STACKABLE COMBUSTIBLES. 7. BEDROOM OUTLETS DO NOT TEST ARC FAULT |