Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2005 | FRAMING | Approved | IVRS - Inspection :* 1) ITEM 03050 NOT APPLICABLE-NO GAS/ALL ELECTRIC |
|
| 10/21/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY SUPER |
|
| 10/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM HEADERS WHERE NEEDED 2) HTT'S NOT NAILED 3) NAIL PROTECT ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD 4) NAIL PROTECT COPPER LINE BOTH SIDES 5) A DIAMETER 2 TRUSS REPAIR HAVE REPAIR AND BY CITY OF TUCSON 6) NO TEST ON DWV'S 7) NAIL PROTECT AB'S AT MASTER BATH 8) SEAL ALL LATH PENETRATIONS |
|
| 08/17/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |