Permit: T05CM03119

Parcel: 138220660

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/24/2005 FRAMING Approved IVRS - Inspection :*
1) ITEM 03050 NOT APPLICABLE-NO GAS/ALL ELECTRIC
10/21/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED ON SITE BY SUPER
10/17/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHIM HEADERS WHERE NEEDED
2) HTT'S NOT NAILED
3) NAIL PROTECT ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD
4) NAIL PROTECT COPPER LINE BOTH SIDES
5) A DIAMETER 2 TRUSS REPAIR HAVE REPAIR AND BY CITY OF TUCSON
6) NO TEST ON DWV'S
7) NAIL PROTECT AB'S AT MASTER BATH
8) SEAL ALL LATH PENETRATIONS
08/17/2005 FRAMING Not ready for Inspection IVRS - Inspection :*