Permit: T05CM03119

Parcel: 138220660

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/07/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/17/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING FROM OUTSIDE
2) HOLDOWN FRONT OF L/R WINDOW, NEED TO RETROFIT WITH EQUAL
3) OVER SPAN UNDER SOUTH EAST WINDOW
4) HOLDOWN RIGHT SIDE OF SOUTH EAST WINDOW NOT NAILED TO TWO KING STUDS
5) SW1 SHEAR REAR OF HOUSE NOT 4' PANEL
6) CHECK SHEAR PANELS (LOCATION)
7) PROVIDE 1/8" GAP ON SIDES AND EDGES OF ROOF PANELS
8) FRAMING WILL BE INSPECTED AT INTERMEDIATES