Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM03107
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/03/2006 | FRAMING | Approved | IVRS - Inspection :* | |
01/26/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PROVIDE APPROVED ENGINEER REPAIR FOR 2-2X 6 OVERBORED STUDS AT SOUTH WALL OK TO INSULATE, LEAVE AREA EXPOSED FOR INSPECTION. SEE LAST INSPECTION |
|
01/19/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PARTIAL PENDING STUD SHOE AT S/W WALL 2) DWV'S OK |
|
01/17/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRAMING WILL BE APPROVED WHEN ALL TRADES ARE COMPLETE 2) SEAL ALL PENETRATIONS AND MISSING STAPLES (LATH) 3) PROVIDE STUD SHOES AT EXTERIOR BEARING WALL 3 SIDES 4) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR 5) NAIL PROTECT T-STAT LINE 6) 3" ABS OUT OF WALL AT N.E. CORNER 8) DWV'S AND WATER LINES OK |