Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM03106
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2006 | FRAMING | Approved | IVRS - Inspection :* | |
03/14/2006 | FRAMING | Cancelled | CANCELLED PER BRIAN OF K.B. HOMES | |
03/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. COMPLETE LATH & SEAL VAPOR BARRIER 2. TIGHTEN ABS 3. 60 DEG. MAX OFFSET @ B-VENT 4. PEX TO CLOSE TO B-VENT 5. FIREBLOCK BY KIT. HOOD 6. FIRESTOP 2ND FLOOR PEN. 7. SUPPORT 2" ABS OVER KIT. 8. FIRESTOP POPOUTS BOTH SIDES OF ENTRY 9. STOPPED INSPECTION. |
|
03/08/2006 | FRAMING | Cancelled | CANCELLED PER BRIAN OF K.B. HOMES |