Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM03098
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
08/24/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WHY DOES YOUR TEST NOT INCLUDE ALL NEW PIPING ? 2) ABS SUPPORTS TO BE NO MORE THAN 4' APART 3) BACK PITCHED SECTION OF VENT NOT PERMITTED 4) TRAP ARMS MAY NOT CHANGE DIRECTION MORE THAN 90 DEGREE WITHOUT ADDITIONAL CLEAN-OUT 5) HORIZONTAL AND HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP |
|
08/23/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) P.O.C. COVERED-MUST BE ABLE TO SEE ALL FITTINGS AND CONNECTIONS 2) CLEAN DEBRIS AND TRASH FROM TRENCH 3) SEE NOTE #4 GENERAL PLUMBING NOTES 4) INSULATE ALL HOT WATER |
|
08/22/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) DOOR LOCKED NO ACCESS |
|
08/16/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* ROUGH SOIL NOT READY NO TEST ON ABS STOPED INP |