Permit: T05CM03068

Parcel: 141017950


Addresses:

6006 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03068

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/16/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/06/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED FLOOR TRUSS FIX GARAGE AND LIVING ROOM
10/04/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) 2 DAMAGED TRUSSES
2) H .25 TIE 2 X 4 NAILER, NEED ANSWER IS IT STRUCTUAL OR CAN IT BE ELIMINATED
09/22/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) BELLY BAND NAILING, OSB TO SHEETROCK
2) NEED APPROVAL FOR TYING SHEAR BOTTOMS TO 2ND FLR
3) H2O5 AT NAILER CEILING AT SHEAR WALLS
4) TWO TRUSSES DAMAGED GARAGE LID AND LID FRONT ROOM
09/20/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TRUSS ROOF - NAIL 2" O.C. STAGGERED ONE FACE THRU OUT
2) BELLY BAND NAILING
3) SHIM ALL 3 PT BEARING
4) TRUSS DAMAGED FRONT AND REAR (FLR TYP)
5) CLIP ALL SHEAR PANELS TOP AND BOTTOM
6) STOP (OVER DRILLING) STUDS FOR PLUMBING
7) CHECK RAT RUNS
8) CHANGE OUT HANGERS AT GIRDER
10D'S OK
9) FILL ALL LARGE HANGERS WITH CORRECT NAILS
10) WHAT ABOUT NAILERS REQUIRING H2.5'S
IS IT STRUCTURAL
11) RAISE EAST SHEAR UP TO FLR
08/26/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OSB TURNED WRONG WAY ON FRONT CABLE
2) MISSING NAILING FRONT REAR
3) SUPPORT VALLEY AT REAR
4) TRUSSES NEED BE DESIGN OR REPAIR
5) HANGERS NOT LARGE ENOUGH TO CARRY LOADS
6) CHECK NAILING IN GLU LAM AND HANGERS