Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM03067
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/22/2005 | FRAMING | Approved | IVRS - Inspection :* | |
11/16/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) ADD NAILS IN FLOOR JOIST HANGERS LIVING ROOM 2) NAIL 2ND ROW OF SHEAR TRANSFER BLKS TOGETHER AT GARAGE 3) WING WALL AT STAIR LOOSE 4) BOTTOM PLATE AT LAUNDRY LOOSE 5) BANG PLATE ROMEX AT 2ND FLOOR CLOSET 6) 2ND FLOOR TUB BACKING (SURROUND) 7) NAIL BANG PLATES AT 2ND FLOOR FOR SHEAR 8) TIE TOP PLATE TOGETHER 2ND FLOOR MASTER BED 9) STUD OVERSPAN MASTER BATH ENTRY 10) SECURE 110 VOLT OUTLET AT MASTER BATH 11) NEED LIGHT SWITCH AT SCUTTLE HOLE |