Permit: T05CM03067

Parcel: 141017940


Addresses:

6002 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03067

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/01/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/04/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) SEE LAST INSPECTION
09/22/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) HANGOR FOR STAIR HEADER
2) BELLY BAND DRYWALL TO OSB SHEAR
3) CHANGE OUT GLU LAMB NAILS/HANGER 16D REQD FRONT ROOM SOUTH
4) SHIM 3PT BEARIN
5) NO RAT RUNS IN MODEL #1356
09/15/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSED NAILING ON ROOF SEE PAINTED AREAS
2) NAIL TRUSS FIX 2" O.C. THRUOUT
3) CLIP FRONT SHEAR TO TRUSSES BOTH SIDES
4) MISSED 4' SHEAR REAR WEST CORNER
5) DBL STUD GIRDER
6) FRONT SHEAR TIE TOP 3 BOTTOM
7) BELLY BAND
8) SHIM 3 PT BEARING TRUSSES
9) CHECK 12" O.C. GABLE TO PLATE NAILING