Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/13/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H.D.'S AND PLATES AT GARAGE SHEAR 2) A.B. AT GARAGE WALL 3) 3" CLEANOUT FOR 1ST FLOOR TRUNK LINE 4) NEED PLAN CHANGE FOR ELIMINATING 2ND 3' WASTE STACK 5) NEED STUD SHOES AT EAST WALL, SISTER STUD REPLUMB BATH ABOVE KITCHEN 6) NEED DETAIL KITCHEN PASS THRU WALL PLATE ANCHORAGE AND BEAM SIZE 7) BLOCK ALL MECH DUCTS 8) HVAC CRUSHED MASTER BATH 9) TUB BACKING 10) BANG PLATES 2ND FLOOR 11) NEED CLARIFICATION FOR CS STRAP AT FRONT SHEAR AT SMALL WINDOWS AT STAIR 12) NEED HVAC INFOR. ATTIC FURN. HEAT STRIP |