Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03058

Parcel: 141017870


Addresses:

5990 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03058

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/18/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/20/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) ADD ADDITIONAL FLOOR TRUSS 19.2" SPACING
2) RE-ENGINEER, PLUMBING WEST WALL BOTH BATHROOMS, OVER DRILLED STUDS
3) TRUSS WEB CUT GARAGE CEILING
4) NEED BLKS FOR GYP BD NAILING GARAGE AT TOP OF WALL
10/04/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) CUT FLOOR TRUSS WEST
2) NEED DETAIL FOR SHEAR TRANSFER AT GARAGE, DBL BLKS INSTALLED NO DETAIL, NAIL PATTERN
3) NEED SHEAR TRANSFER FRONT/ENTRY
09/26/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) REPLACE VERT GABLE TRUSS MEMBER EAST
2) TOE NAIL TOP CHORD TO PLATE EAST
3) BELLY BAND DRYWALL NAILING GARAGE (DETAIL)
4) FLOOR TRUSSES, CUT FOR PLUMBING
5) TIE SHEARWALLS DOWN BOTTOMS (NEED DETAIL)
09/20/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
WALK HOUSES BEFORE CALLING IN