Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03030

Parcel: 103191080

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03030

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/31/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/26/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 6 PHAD 42' MISSING REAR
2) WIND BRACING MISSING SOUTH SIDE
3) NAILS SET TOO DEEP ON ROOF INTO TRUSS AT GARAGE SHEAR
4) NAILS MISSING ROOF NAILING INTO BLOCKING AT TRUSS BEARING
08/17/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL STRAPS EXT. BOTTOM PLATES AT PLUMBING CUTS
2) NEED PLAN TO CHECK SHEAR; NAILING ETC...
3) NEED LADDER