| 08/31/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 6 PHAD 42' MISSING REAR 2) WIND BRACING MISSING SOUTH SIDE 3) NAILS SET TOO DEEP ON ROOF INTO TRUSS AT GARAGE SHEAR 4) NAILS MISSING ROOF NAILING INTO BLOCKING AT TRUSS BEARING |
|
| 08/17/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL STRAPS EXT. BOTTOM PLATES AT PLUMBING CUTS 2) NEED PLAN TO CHECK SHEAR; NAILING ETC... 3) NEED LADDER |