Permit: T05CM03023

Parcel: 114480850

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/29/2005 FRAMING Approved IVRS - Inspection :*
11/23/2005 FRAMING Partial Approval IVRS - Inspection :*#1 N.R OK TO INSULATE
11/21/2005 FRAMING Partial Approval IVRS - Inspection :*
1) FIRE BLOCK TUBS
2) PROVIDE 1 1/2" CLEARANCE TO FIREPLACE VENT
3) ADD WEEP SCREED SOUTH EAST CORNER
4) ADD RECEPTACLE MASTER VANITY
5) NO PRESSURE TEST
6) NO DWV TEST
7) SUPPORT ABS EVERY 4'
8) NEED 1" CLEAR TO B-VENT AT ROOF 2 PLACES AND AT FURR DOWN
9) RE-ROUTE STAT WIRE
10) TAPE DRYER VENT