Date Description Inspector Results Comments
10/18/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/14/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL 4 MISSED ROWS OF ROOF NAILING ON UPPER ROOF-N.W. CORNER
2) NAIL OFF EAST 2ND FLOOR WALL SHEATHING
3) STRAP NON CABIN TIEDS-1ST AND 2ND FLOOR AT S.E. CORNER
4) MISSING TJI HANGER IN GARAGE
5) FINISH WALK DECK FRAME AND SHEATHING