Permit: T05CM03022

Parcel: 114480840

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/18/2005 FRAMING Approved IVRS - Inspection :*
11/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCKS MISSING GARAGE SHEAR WALL
2) FASTENING OK
3) CAULK ELECTRIC BOXES AND J-METAL AT PORCH POSTS
4) IF BAR TOP EXTENDS OVER 6", REMOVE RECEPTACLE FROM L/R SIDE
5) GROUT TUBS AND REPAIR FLOORS
6) CONNECT LAUNDRY EXHAUST
7) ITEMS NOT NOTED APPEAR OK
8) NO PLANS ON SITE TO CONFIRM FRAMING H.D.'S ETC...