Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03020

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/06/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/02/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO COVER EXTERIOR
2) RETRO H.D. ON EAST WALL NOT DONE
3) SHEAR TRANSFER NOT PER PLAN KITCHEN SHEAR
4) MISSING HANGERS ON ROOF HIPS
11/30/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE PRIOR ITEMS
11/25/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NO PLANS OR PERMIT POSTED
11/18/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) RESOLVE PRIOR ITEMS
2) PLAN SHOWS BEARING WALL EXTENDED UNDER TRUSS
11/15/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO TRUSS DRAWINGS ON SITE
2) FILL GAP BETWEEN PLATES AND HEADER AT POINT LOAD, DIAGONAL WALL ABOVE DOOR, KITCHEN STAIR AREA GLU LAM BEAM SUPPORT
3) DETAIL T.J.I.'S TO 2 X 12, HOW MANY NAILS REQUIRED INTO TRUSS IS ADAQUATE ?
4) CHECK HANGER SIZE, TYPE, AND NAILS SIZED PER MANUFACTURER
5) END TRUSS GARAGE NO HANGER NAIL OFF TO WALL
6) SHIM ALL 3 PT BEARING TRUSSES
7) 1ST AND 2ND FLOOR TIES EAST
8) STRAP BEAM AT FRONT ENTRY PORCH TO COLUMN
9) SHEARWALL #5 AT KITCHEN USE 8/DT2 SHEAR TRANSFER
10) MISSED HPA22 EAST WALL
11) #5 SHEAR AT KITCHEN NOT INSTALLED
12) DBL TRUSS KITCHEN AREA HUNG ON CANTILIVERED 2 X 10
13) MISSING NAILING TO HANGERS AT TJI AT LEDGERS
14) MISSING HANGERS AT ROOF HIP TRUSSES
15) MISSING NAILING UPPER FRONT HIP
16) CROSS REFERENCE T.J.I. 20'S WITH ONES USED IN LIVING
ROOM
17) BLK AND NAIL OSB GARAGE HIP RUN PARALLEL TO TRUSSES
18) FRONT ENTRY P.A. TO ALIGN WITH SHEAR ABOVE