Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM03013
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/29/2005 | FRAMING | Approved | IVRS - Inspection :* | |
12/28/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) H20 TEST OK ON DWV 2) INSTALL BANG PLATES ELECTRIC HOLES DRILLED WITHIN 1 1/4" OF FACE OF STUD 3) INSTALL BANG PLATES PLUMBING HOLES DRILLED WITHIN 1 1/2" FACE OF STUD 4) NO TEST POTABLE WATER |
|
12/23/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL ALL PENETRATIONS THRU VAPOR BARRIER 2) TIGHTEN ALL AB'S 3) RE-ALLIGN HOLE FOR HOME RUNS INTO PANEL 4) BANG PLATES ON ELECTRIC THROUGHOUT 5) BANG PLATE 3" ABS AT BOTTOM PLATE AND 2" IN BATH 6) TEST ON POTABLE WATER |