Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/08/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) REPAIR FIREBLOCK GAS PIPE GARAGE 2) FILL HOLES TJI HANGERS FRONT BEDROOM 3) 1 HANGER MISSING FRONT HALL |
|
| 12/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK HOME RUN BAY AND REPLACE BLOCKS AT MECH PLATFORM, EAST OF KITCHEN DINING WINDOW AND STOVE VENT 2) SHIM TRIMMER/HEADER CONNECTIONS WHERE NEEDED 3) INSTALL NAIL PLATES FOR WIRES UNDER LIVING WINDOW AND MASTER EAST WINDOW 4) SECURE MASTER BED 4 GANG BOX AND FIRE BLOCK CHASE ABOVE AND ENTRY 4 GANG 5) PROVIDE 1" TO COMBUSTIBLES AT MASTER WATER HEATER FLUE 6) CAULK WOOD/FOAM INTERSECTIONS |