Permit: T05CM02881

Parcel: 13322500G

Inspection Status: Approved

Inspection History: ELECTRIC - ABOVE CEILING

Date Description Inspector Results Comments
09/29/2005 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection :*
09/18/2005 ELECTRIC - ABOVE CEILING Partial Approval IVRS - Inspection :*
OK TO TILE
09/15/2005 ELECTRIC - ABOVE CEILING Partial Approval IVRS - Inspection :*
1) NEED REJECTION PINS AND FUSES
2) SERVICE FOR 7137 OK
3) FINISH #2 PREVIOUS INSPECTION
09/13/2005 ELECTRIC - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
1) FIXTURES TO BE SUPPORTED TO GRID. IF MANUFACTURERS CLIPS ARE USED THEY NEED TO BE EFFECTIVE 410.16
2) MANUFACTURER WIRING TO BE SUPPORTED AS PER 300.11 AND 604.6 (E), 110.3 AND 330.30
3) VDV CABELING TO BE AS PER 725.6 AND 800.6
4) BOXES IN CEILING NEED SUPPORT WIRES
5) M/C CABLE TO BE TERMINATED
6) FINISH SUPPORT WIRES TO FIXTURES
7) REMOVE ABANDONED NM CABLE
8) CAP UNUSED RELOCK ENDS