Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02880
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2005 | FRAMING | Approved | IVRS - Inspection :* | |
08/16/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) EXT. CLIP HOLDOWNS NOT INSTALLED 2) NO DWV WATER TEST 3) GARAGE SHEARWALL HOLDOWNS NOT INSTALLED 4) BLOCK DUCT BOOTS 3-SIDES 5) NMB CABLE CANNOT BE ENCASED IN CONCRETE. USE UF CABLE AT ISLAND 6) WALLS NOT ANCHORED 7) STOPPED INSPECTION-TO MANY ITEMS |