Permit: T05CM02849

Parcel: 137294300

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/18/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/16/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWNS REAR NEED TO BE RETRO FITTED, HOLDOWNS NOT NAILED TO TWO KING STUDS
2) NAIL PROTECT PLUMBING FROM OUTSIDE
3) PROVIDE 1/8" GAP AT ROOF SHEATHING
4) STAPLES STICKING UP AT ROOF SHEATHING
5) WIND BRACE WEST TO SHORT
02/14/2006 EXT METAL CLIPS/EXT SHEATHING Cancelled CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR C. TREVILLYAN
02/13/2006 EXT METAL CLIPS/EXT SHEATHING Cancelled CANCELLED PER RON WITH RICHMOND AMERICAN