Permit: T05CM02837

Parcel: 10711140A


Addresses:

350 W DELANO ST #01

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/31/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/30/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. NEED SWITCHED OUTLET OR LIGHT FIXTURE (WORKING) IN EACH HABITABLE ROOM PER NEC 210.70
03/23/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. STILL NEED TO COMPLETE CORRECTIONS #4, #7, #8 FROM PREVIOUS INSPECTION.
03/13/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
03/10/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. OUTLET BOXES IN CABINETS TO BE FLUSH WITH SURFACE 2002 NEC 314.20
2. INSTALL ANTI-TIP BRACKET ON RANGES NEC 110.3 (B)
3. ALL SWITCHES NEED EQUIPMENT GROUND CONNECTED TO THEM NEC 404.9 (B) - HAVE COVERS OFF NEXT INSPECTION.
4. NEED LIGHT OR SWITCHED OUTLET IN FAMILY ROOM
NEC 210.70
5. TIGHTEN ALL LOOSE OUTLETS - SECURE TO WALL
NEC 406.4(A)
6. MASTER BATH LIGHT SWITCH UPSIDE DOWN NEC 110.3(B)
7. BEDROOMS NEED LIGHT OR SWITCHED OUTLETS NEC 210.70
8. MAKE A.C. DISCONNECTS AND OUTLETS SECURE 110.13(A)
UNIT 1 INSPECTION ONLY CHECK FOR BOTH UNITS
9. INSTALL EXTERIOR LIGHT FIXTURES AND BULBS
NEC 210.70 (2)