Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/31/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/28/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 12/23/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
| 12/21/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
| 12/19/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
| 12/16/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) WRAP GROUND COMPLETELY AROUND GROUND SCREW ON ALL METAL BOXES 2) INSTALL NAIL PLATES WHRE ROMEX IS LESS THAN 1 1/4" FROM STUD FACE 3) COMPLETE SERVICE WIRING AND EXTEND SERVICE SHEATHING INTO ENCLOSURES 4) PROVIDE BUSHING FOR #4 AND LARGER CONDUCTORS 5) BLANK OFF UN-USED OPENINGS IN SUB-PANELS |
|
| 12/14/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* COULD NOT LOCATE PLANS/PERMIT RECALL INSP. |