Permit: T05CM02837

Parcel: 10711140A


Addresses:

350 W DELANO ST #01

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
03/31/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
12/28/2005 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
12/23/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
12/21/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
12/19/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
12/16/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) WRAP GROUND COMPLETELY AROUND GROUND SCREW ON ALL METAL BOXES
2) INSTALL NAIL PLATES WHRE ROMEX IS LESS THAN 1 1/4" FROM STUD FACE
3) COMPLETE SERVICE WIRING AND EXTEND SERVICE SHEATHING INTO ENCLOSURES
4) PROVIDE BUSHING FOR #4 AND LARGER CONDUCTORS
5) BLANK OFF UN-USED OPENINGS IN SUB-PANELS
12/14/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
COULD NOT LOCATE PLANS/PERMIT RECALL INSP.