Permit: T05CM02835

Parcel: 12213045A


Addresses:

3901 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/24/2006 ELECTRIC - INTERMEDIATE Approved
02/17/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
02/16/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
02/15/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) USE AN APPROVED EXTENDER BOX FOR CEILING
2) REMOVE LIGHTING TO INSPECT WIRING METHODS
3) AREAS OCCUPIED WITHOUT INSPECTIONS
4) SUPPORT M/C CABLES AS PER CODE-ALSO FLEX CONDUITS
5) TIGHTEN LOOSE FITTINGS
6) NM CABLES TO BE SECURED TO BOX
7) FILL UNUSED OPENINGS IN BOXES
8) PROTECT FLEX CONDUIT AT STUDS
9) SUPPORT N M CABLE WITHIN 12" OF BOXES
01/26/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*OK ROOM CASHER BOOTH
01/23/2006 ELECTRIC - INTERMEDIATE Cancelled IVRS - RI canceled
01/19/2006 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. INSTALL VDV CABLING AS PER APPLICABLE CODES
12/30/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. PLANS SHOW NO ELECTRIC - WE HAVE 2 NEW RECEPTACLES ON AN EXISTING CIRCUIT - WHAT IS OUR LOAD? WHERE ARE THEY LOCATED.
2. FINISH PREVIOUS NOTES FROM LAST INSPECTION
12/23/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*PROTECT M/C CABLE AT STUDS 300.4 ALSO FLEXWHERE ARE CITY APPROVED SET OF PLANS?
NOTE 725.2 & 6, 800.2 & 6 WILL APPLY TO VDV CABLEING