Permit: T05CM02834

Parcel: 140106640

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/13/2005 ROOF NAILING Approved IVRS - Inspection :*
07/05/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OPEN UP COLUMNS-PLANS CALL FOR 4 X 6 (2) 2 X 4'S INSTALLED. ALSO PROPER PORT BASE INSTALLED ANCHOR BOLTS LOOSE
2) LEDGER NOT LAY BOLTED TO WALL PER PLAN
3) ADD A35 TO FLY RAFTERS AND LEDGER
4) PROVIDE LADDER FOR ACCESS TO ROOF
5) STRAP BEAMS WHERE JOINED AT POST FHA STRAP
6) PROVIDE METAL FLASHING ON TOP OF LEDGER TO AVOID MOISTURE PENETRATION
7) 1" MINIMUM CLEARANCE FOR WEEP SCREED CONCRETE