Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM02818

Parcel: 140325420


Addresses:

3966 E NICO LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM02818

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/31/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED APPROVED TRUSS DRAWINGS
2) INTERIOR SHEAR TRANSFER AT GARAGE INCOMPLETE DETAIL 13-DTS
3) LATHE INCOMPLETE
4) GABLE END HINGE BRACING NOT INSTALLED PER DETAIL 6 DTI
5) SIMPSON ST2115 ON INSIDE GARAGE HEEDEES? AT BEARING MISSING
6) INTERIOR BEARING WALLS TO BE CLIPPED TOP AND BOTTOM
7) BOTTED? TO CONCRETE
8) STOPPED INSPECTION
08/23/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
08/19/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) HOLD DOWNS ON CENTER SHEARWALL WRONG LOCATIONS
08/15/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) HOLDOWNS AT REAR OF HOUSE CENTER SHEARWALL HOLDOWNS (2) ARE IN WRONG LOCATION-PROVIDE RETRO FIT HOLDOWN