Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM02795
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/19/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS MADE OK 2) PLUMBING FINAL OK 3) OK FOR C OF O PENDING ANY OTHER INSPECTION |
|
08/18/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) ONLY ONE SLIP NUT ON THE OUTLET SIDE OF P-TRAP 2) SINKS REQUIRE CLEANOUTS 3) TRAP AND TRAP ARM TO BE THE SAME SIZE. TRAP ARM TO BE INSTALLED AT 1/4" PER FOOT |
|
08/15/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. MINIMUM SIZE WASTE LINE FOR A KITCHEN SINK IS 2 INCH. 2. PRESSURE FITTINGS MAY NOT BE USED FOR DWV 3. CONNECTIONS BETWEEN DISSIMILAR MATERIAL TYPES TO BE APPROVED TYPE. 4. NO CLEAN OUT FITTING AT KITCHEN SINK. 5. CONTINUOUS WASTE TEE TO BE INSTALLED IN A VERTICAL POSITION. |
|
08/08/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PLEASE CALL IN THIS PERMIT AND YOUR GAS PERMIT AT THE SAME TIME 2) PRESSURE FITTINGS NOT APPROVED-USE STANDARD RECESSED THREADED FITTINGS |
|
08/05/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PULL AND REPLACE PLUMBING FIXTURES-OK 2) KITCHEN SINK MISSING VENT 3) KITCHEN SINK DRAINS NEED TO BE RE-PLUMBED |