Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM02790
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CALL IN 03040 & 03090 CLOSET FLANGE SHALL HAVE SMOOTH INTERIOR WATER WAY FOR RISER PIPE WITH PIPE FLUSH TO TOP OF CLOSET FLANGE. THIS REQUIRES A DUTCHMAN. |
|
03/30/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF OK WATER PIPING IN RESTROOM BACK TO RP LOCATION 60 PSI TEST 1. NEED TO SEE CLOSET FLANGE PRIOR TO SETTING STOOL. NOTE CHECK 16"-18" ADA REQUIREMENT FOR SIDE WALL CLEARANCE. |