Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
Permit Number - T05CM02778
Inspection Description - STUCCO MESH
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2005 | STUCCO MESH | Approved | IVRS - Inspection :* | |
| 10/26/2005 | STUCCO MESH | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FASTEN UPSTAIRS EYEBROWS 6" ON CENTER |
|
| 10/25/2005 | STUCCO MESH | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FASTEN 6" ON CENTER ALL EYEBROWS AND PORCHES 2) SEAL ALL PENETRATIONS 3) FASTEN 6" ON CENTER TOP PLATE EAST WALL/COMPLETE ENTRY COLUMN 4) FIRE BLOCK W/H PLENIUMN 5) NO WATER TEST DWV OR PLASTIC 6) MISSING AB LIVING ROOM EAST WALL 7) FIREBLOCK ENTRY CLOSET 8) FIREBLOCK UPSTAIRS BEDROOM 2 CLOSET 9) BLOCK TUB WALLS 10) NAIL PROTECT VENT PIPE MASTER CLOSET 11) FIRESTOP DUCT WORK AT FIRST FLOOR MASTER BEDROOM 12) INSTALL TJI AT SKY LIGHT MASTER BATH 13) NAIL PROTECT THROUGHOUT PLUMBING UNDER 1 1/2" 14) AB MISSING GARAGE EAST WALL AND WEST WALL 15) RAISE W.H. FROM FLOOR FOR PROTECTION |