Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM02777
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING CLIPS 2) PROVIDE BLOCKING SW-2 WALL AT PATIO 3) NAIL PROTECT ALL EXTERIOR PLUMBING UNDER 1 1/2" AT BOTTOM PLATES 4) WIND BRACING 2 EACH 16D COMMONS TOP AND BOTTOM PLATES 5) A.35 AT ALL EYEBROWS AND PORCHES 6) TOP STORY ROOF 1/8" GAP NEEDED OSB ENDS 7) LOOSE SHEET N.E. CORNER, BOTTOM LEVEL OK |
|
| 10/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |