Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM02775

Parcel: 118043080


Addresses:

1304 S FLAXSEED DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM02775

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/04/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP NORTH SIDE NOT NAILED
2) PATIO MISSING BIRD BOARDS
3) COMPLY WITH DETAIL 7SD3
4) OVERSPAN WEST WALL 2ND FLOOR
5) HOLDOWN S/W CORNER OVERSPALLED, PROVIDE RETRO FIT PER PLAN
6) STOPPED INSPECTION, SUPER DID NOT WALK HOUSE