Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2005 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 12/19/2005 | SHEET ROCK NAILING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection No change from 12/14/05 and 12/16/05 You have 5 days to pay reinspection fee |
|
| 12/16/2005 | SHEET ROCK NAILING | Denied | IVRS - Inspection : The drywall is not nailed per code.| 175* 1) GARAGE CEILING NOT SECURED AT 6" ON CENTER-SEE ITEM 1 FROM 12/13/05 |
|
| 12/14/2005 | SHEET ROCK NAILING | Cancelled | IVRS - RI canceled | |
| 12/13/2005 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GARAGE CEILING MUST USE 1 7/8" NAILS OR 1 1/2" SCREWS AT 6" ON CENTER PER IRC TABLE 702.3.5 NOTE E 2) HOUSE OK TO TAPE NOT GARAGE CEILING |