Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02769
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/17/2006 | FRAMING | Approved | IVRS - Inspection :* | |
01/11/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 2, 4, 7 AND 8 NOT DONE FROM INSPECTION DATED 01/09/06 |
|
01/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL ALL LATH PENETRATIONS AND MISSING STAPLES 2) WIRSBO MUST BE 6" AWAY FROM B-VENT 3) B-VENT HAS NEGATIVE PITCH 4) DIRTY ARM IN POWDER ROOM EXCEED 42" 5) METAL BOXES NOT GROUNDED 6) NO TEST ON DWV'S UPSTAIRS 7) SECURE GAS LINE AT FAU 8) ATTIC ACCESS OBSTRUCTED |