Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02748
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/30/2005 | FRAMING | Approved | IVRS - Inspection :* | |
09/29/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK FURNACE PLENIUM 2) WINDOWS AND DOORS LACK TRIMMERS |
|
09/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* STOPPED INSPECTION INSTALL WINDOWS INSTALL H-2.5 5 TOP AND BOTTOM STUDS EXTERIOR WALLS INSTALL BATH EXHAUST TO EXTERIOR GROUND METAL BOXES COMPLETE FRAMING AROUND FURNACE ROOM AND CLOSET SECURE AND STAPLE ROMEX TO WALL 1" CLEARANCE H2O HEATER FLUE TO COMBUSTIBLE |
|
09/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* COMPLETE ALL AND RECALL 1" CLEARANCE H2O HEATER FLUE TO COMBUSTIBLES INSTALL WIRES AND WEATHERHEAD BEAM ELECTRIC SERVICE GROUND METAL ELECTRIC BOXES COMPLETE ALL ELECTRIC INSTALL STUCCO STOP AND ADDITIONAL NAILING EXTERIOR LATHE BLOCK AND SIDES DUCTS THROUGH CEILING INSTALL H2-5'S TOP AND BOTTOM STUDS TO PLATES INSTALL BATH EXHAUST DUCT TO EXTERIOR INSTALL METAL ENCLOSURE H2O HEATER EXTERIOR INSTALL DROPPED CEILING FURNACE ROOM STOPPED INSPECTION |
|
09/08/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE COVER AROUND H2O HEATER FLUE PIPE - MUST HAVE 6" CLEARANCE PIPE TO COMBUSTABLES AT ROOF LINE 2) REMOVE ALL OLD ELECTRIC OUTSIDE NEXT TO H2O HEATER 3) UNCOVER GROUND RODS (2) AT NEW SERVICE PANEL 4) INSTALL WEATHER END AND CONDUCTORS NEW SERVICE PANEL 5) WIRES HANGING LOOSE, TERMINATE IN BOXES, GROUND ALL METAL BOXES 6) INCOMPLETE, ITEMS NOT CONNECTED 7) REFEE DUE 8) STOPPED INSPECTION |
|
07/27/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK 3 SIDES CEILING DUCTS 2) COMPLETE ELECTRIC 3) INSTALL INTER CONNECTED SMOKE DETECTORS ALL BEDROOMS AND HALLS OUTSIDE BEDROOMS 4) INSTALL RISER AND CONDUCTORS NEW SERVICE PANEL 5) UNCOVER GROUND RODS NEW SERVICE PANEL 6) COMPLETE DROPPED CEILING FURNACE CLOSET AND HALL 7) DELETE CEILING FAN AND GAS WALL HEATER FROM PLANS-NOT USED 8) COMPLETE ALL TRADES AND RECALL FOR ALL INSPECTIONS |
|
07/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER TEST DWV TO GO THROUGH ROOF 2) NEED PERMITS/INSPECTION SOIL PIPE AND SEWER AND UNCOVER AND H20 TEST 3) BLOCK 3 SIDES MECH REGISTER DUCTS CEILING 4) INSTALL BANG PLATES ALL PLUMBING AND ELECTRIC HOLES IN STUDS 5) CEILING FAN BOXES NOT INSTALLED 6) ELECTRIC INCOMPLETE 7) STOPPED INSPECTION 8) MUST COMPLETE ALL TRADES THEN CALL FOR ALL INSPECTIONS |
|
06/22/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL FRAMING, ELECTRIC, MECH, PLB, GAS, ETC...THEN RECALL |