Permit: T05CM02748

Parcel: 107080010


Addresses:

701 W GLENN ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02748

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/30/2005 FRAMING Approved IVRS - Inspection :*
09/29/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCK FURNACE PLENIUM
2) WINDOWS AND DOORS LACK TRIMMERS
09/20/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
STOPPED INSPECTION
INSTALL WINDOWS
INSTALL H-2.5 5 TOP AND BOTTOM STUDS EXTERIOR WALLS
INSTALL BATH EXHAUST TO EXTERIOR
GROUND METAL BOXES
COMPLETE FRAMING AROUND FURNACE ROOM AND CLOSET
SECURE AND STAPLE ROMEX TO WALL
1" CLEARANCE H2O HEATER FLUE TO COMBUSTIBLE
09/14/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLETE ALL AND RECALL
1" CLEARANCE H2O HEATER FLUE TO COMBUSTIBLES
INSTALL WIRES AND WEATHERHEAD BEAM ELECTRIC SERVICE
GROUND METAL ELECTRIC BOXES
COMPLETE ALL ELECTRIC
INSTALL STUCCO STOP AND ADDITIONAL NAILING EXTERIOR LATHE
BLOCK AND SIDES DUCTS THROUGH CEILING
INSTALL H2-5'S TOP AND BOTTOM STUDS TO PLATES
INSTALL BATH EXHAUST DUCT TO EXTERIOR
INSTALL METAL ENCLOSURE H2O HEATER EXTERIOR
INSTALL DROPPED CEILING FURNACE ROOM
STOPPED INSPECTION
09/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE COVER AROUND H2O HEATER FLUE PIPE - MUST HAVE 6" CLEARANCE PIPE TO COMBUSTABLES AT ROOF LINE
2) REMOVE ALL OLD ELECTRIC OUTSIDE NEXT TO H2O HEATER
3) UNCOVER GROUND RODS (2) AT NEW SERVICE PANEL
4) INSTALL WEATHER END AND CONDUCTORS NEW SERVICE PANEL
5) WIRES HANGING LOOSE, TERMINATE IN BOXES, GROUND ALL METAL BOXES
6) INCOMPLETE, ITEMS NOT CONNECTED
7) REFEE DUE
8) STOPPED INSPECTION
07/27/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK 3 SIDES CEILING DUCTS
2) COMPLETE ELECTRIC
3) INSTALL INTER CONNECTED SMOKE DETECTORS ALL BEDROOMS AND HALLS OUTSIDE BEDROOMS
4) INSTALL RISER AND CONDUCTORS NEW SERVICE PANEL
5) UNCOVER GROUND RODS NEW SERVICE PANEL
6) COMPLETE DROPPED CEILING FURNACE CLOSET AND HALL
7) DELETE CEILING FAN AND GAS WALL HEATER FROM PLANS-NOT USED
8) COMPLETE ALL TRADES AND RECALL FOR ALL INSPECTIONS
07/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER TEST DWV TO GO THROUGH ROOF
2) NEED PERMITS/INSPECTION SOIL PIPE AND SEWER AND UNCOVER AND H20 TEST
3) BLOCK 3 SIDES MECH REGISTER DUCTS CEILING
4) INSTALL BANG PLATES ALL PLUMBING AND ELECTRIC HOLES IN STUDS
5) CEILING FAN BOXES NOT INSTALLED
6) ELECTRIC INCOMPLETE
7) STOPPED INSPECTION
8) MUST COMPLETE ALL TRADES THEN CALL FOR ALL INSPECTIONS
06/22/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL FRAMING, ELECTRIC, MECH, PLB, GAS, ETC...THEN RECALL