Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM02731
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2005 | BUILDING - FINAL | Approved | ||
| 11/01/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*H.C PARKING SIGNS TO BE MOUNTED 84" ABOVE GRADE PER TUCSON CITY CODE/ CURB RAMP MAY NOT EXCEED 1/12( 8.33%) MAIN ENTRANCES REQUIRED TO HAVE SIGN "THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED" REMOVE EXIT SIGN OR DEADBOLT FROM REAR DOOR. IF YOU WANT YOUR NORTH AND SOUTH FRONT DOORS TO BE REQUIRED EXITS THEN REMOVE EXIT SIGN AT REAR AND SEE NOTE 3 ABOVE FOR NORTH AND SOUTH FRONT DOORS/ WATER CLOSETS TO BE 34" MAX TO RIM VERTICAL GRAB BARS BELONG 39"MIN AND 41" MAX FROM REAR WALL " DOOR TO REMAIN UNLOCKED" SIGNS ARE AN EXCEPTION TO THE CODE THAT IS ONLY ALLOWED AT MAIN ENTRANCES. |
|
| 10/31/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*DOOR LOCKED NO ACCESS |
|
| 10/26/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :*MUST HAVE ALL OTHER FINALS AND C OF O. APPROVALS PRIOR TO BUILDING FINAL. |