Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02716

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/14/2005 FRAMING Approved IVRS - Inspection :*
11/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPLACE CRUSHED STOVE DUCT
2) SEAL TUB HOLES IN FLOOR
3) SHIM TRIMMERS/HEADERS WHERE NEEDED
4) REPLACE BROKEN DBL BLOCK IN LAUNDRY
5) SHIM HEADER AT TOP OF UPPER STRINGERS
6) FHA STRAP OVER BORE IN TOP PLATES IN INTERIOR BEARING WALL IN DOWN BEDROOM
7) BANG PLATE SMART WIRE HOME RUNS
8) NEED OUTLET AT MASTER SINK
9) BLOCK MASTER DUCT BOOT
10) FIREBLOCK UPPER HALL NITCH AND AT ENTRY CAN LIGHT AREA
11) TRANSFER GIRDER TRUSS LOADS 2ND TO 1ST FLOOR