Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T05CM02716

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
10/12/2005 ROOF NAILING Approved IVRS - Inspection :*
10/11/2005 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
10/11/2005 ROOF NAILING Partial Approval IVRS - Inspection :*
1) APPROVED TO ROOF PATIO/DECK
2) RETRO HOLDOWN S.W. CORNER-CHECK AT INTERMEDIATE
3) STRAP GLU LAM AND POST AT LOFT BOTTOM
4) 2ND FLOOR SHEAR AT LOFT ?
5) COMPLETE SHEAR NAILING
6) COMPLETE ROOF NAILING
10/05/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILS TO DEEP ON GARAGE SHEAR
2) TIE BACK PATIO DOWN TO CENTER COLUMN
3) RETRO HOLDOWN S.W. CORNER-CHECK AT INTERMEDIATE
4) H2.5 ON TOP PLATE AT ENTRY AREN'T CONNECTING DBL TOP PLATE
5) STRAP GLU LAM AND POST AT LOFT
6) BOTTOM HANGERS REQUIRED ON TJI AT LOFT
7) CLIP HIP JACKS-2ND FLOOR
8) DBL STUDS UNDER GIRDERS-2ND FLOOR
9) SHIM AND CLIP 2ND FLOOR BEARING WALLS
10) 2ND FLOOR SHEAR AT LOFT ?
11) COMPLETE SHEAR NAILING
12) COMPLETE ROOF NAILING
13) STOPPED INSPECTION