Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM02712
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/11/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIE GLU LAM DOWN AT LOFT BOTTOM 2) CLIPS REQUIRED ON GIRDER JACK AT LOFT 3) STRAP TOP PLATES AT LOFT 4) SHEARWALL AT LOFT ? 5) PIN GARAGE SHEARWALL TO FLOOR |
|
10/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLIP STUDS AND RAFTERS ON SOUTH BAY 2) CONTINOUS TIE (ROOF TO CONCRETE) ENTRY 3) STRAP BEAM TO WALL AT STAIRWAY 4) DBL STUDS UNDER GIRDER TRUSSES-2ND FLOOR 5) TIE GLU LAM DOWN AT LOFT 6) CLIP HIP JACKS AT LOFT 7) CLIPS AND HANGERS REQUIRED ON GIRDER JACK AT LOFT 8) STRAP TOP PLATES AT LOFT 9) NAIL SHEATHING TO BOTTOM PLATE WEST WALL-2ND FLOOR 10) BLOCK VALLY ROOF SHEATHING 11) TIE GIRDER AT ENTRY TO WALL 12) SHEARWALL AT LOFT ? 13) TRUSS SPECS ON SITE 14) FIREWALL AT MECH PLATFORM 15) STOPPED INSPECTION |