Date Description Inspector Results Comments
10/13/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/11/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIE GLU LAM DOWN AT LOFT BOTTOM
2) CLIPS REQUIRED ON GIRDER JACK AT LOFT
3) STRAP TOP PLATES AT LOFT
4) SHEARWALL AT LOFT ?
5) PIN GARAGE SHEARWALL TO FLOOR
10/05/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP STUDS AND RAFTERS ON SOUTH BAY
2) CONTINOUS TIE (ROOF TO CONCRETE) ENTRY
3) STRAP BEAM TO WALL AT STAIRWAY
4) DBL STUDS UNDER GIRDER TRUSSES-2ND FLOOR
5) TIE GLU LAM DOWN AT LOFT
6) CLIP HIP JACKS AT LOFT
7) CLIPS AND HANGERS REQUIRED ON GIRDER JACK AT LOFT
8) STRAP TOP PLATES AT LOFT
9) NAIL SHEATHING TO BOTTOM PLATE WEST WALL-2ND FLOOR
10) BLOCK VALLY ROOF SHEATHING
11) TIE GIRDER AT ENTRY TO WALL
12) SHEARWALL AT LOFT ?
13) TRUSS SPECS ON SITE
14) FIREWALL AT MECH PLATFORM
15) STOPPED INSPECTION