Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/26/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/20/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RED HEAD MASTER BED BAY WINDOW PLATE AT JOINT 3-12" EACH SIDE 2) COMPLETE KITCHEN REGISTER BOX-BLOCK 3 SIDES 3) BLOCK NEW MASTER GARDEN TUB WALLS FOR NAILING 4) PROVIDE CONTINOUS TIE DOWN AT KITCHEN BEAM TO ALL POSTS 5) OK TO INSULATE 6) EXPOSE ABOVE AREAS |
|
| 01/17/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REINFORCE WINDOWS AND DOORS EXCEPT EXISTING HOUSE 2) PENDING MASTER TUB 3) RED HEAD ALL BASE PLAN JOINTS 3-12" 4) BLOCK TUB WALLS 5) LOOSE OUTLET BOX GREAT ROOM EAST WALL 6) COMPLETE REGISTER BOX TO KITCHEN |