Permit: T05CM02677

Parcel: 14026001J

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESS TEST FNL

Permit Number - T05CM02677

Inspection Description - PLUMBING - GAS PRESS TEST FNL

Inspection Status - Denied

Date Description Inspector Results Comments
02/03/2006 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECT LEAK ON T&P DRAIN
USE CORRECT DRAINAGE FITTING FOR VENTING BELOW FLOOD RIM
T&P SHALL TERMINATE 6"-24" ABOVE GRADE
INTER MEMBERING OF DISSIMILAR METALS IS PROHIBITED IN NEW CONSTRUCTION
USE PROPER C/O PLUG TO ACCEPT C/O SCREW USED TO HOLD C/O COVER IN PLACE - DRILLING OR TAPPING ABS IS PROHIBITED