Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02672
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/02/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK ALL MECH. BOOTS 3 SIDES MIN 2) PROVIDE NAIL PROTECTION OVER PEX LINES IN MASTER BATH 3) FIREBLOCK PLATFORM IN BEDROOM CLOSET 4) PROVIDE 1" CLEARANCE TO COMBUSTABLES AROUND H20 HEATER FLU 5) PROTECT WATER AND ELECTRICAL LINES EXITING TOP OF KITCHEN WALL 6) GROUND METAL LIGHT BOXES IN KITCHEN / DINING 7) PROVIDE HURRICANE CLIPS AT BOTTOM OF RAFTERS IN KITCHEN / DINING 8) SUPPORT END OF BEAM OF KITCHEN CEILING |