Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 06/20/2005 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection :* |
| 06/16/2005 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection :* 1) CITY APPROVED PLAN TO BE ON SITE AT TIME OF INSPECTION. 2) 3005 INSTALLATION IS NOT PER YOUR UN APPROVED PLAN. 3) 3040 PIPING REQUIRES FITTINGS FOR CHANGE OF DIRECTION. 4) 3055 TEST W?? IS NOT INSTALLED CORRECTLY AND REQUIRE MINIMUN 1/4" PER FOOT ??? AT HCS CONNECTION TO TEST WYE. 5) PLEASE PIPING UNDER SLAB SHALL HAVE SEPARATION BETWEEN HOT & COLD TUBING. PLEASE HAVE PLUMBING CONTRACTOR ON SITE FOR INSPECTION. NOT A COMPLETE LIST. |