Permit: T05CM02662

Parcel: 136384680

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
06/20/2005 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
06/16/2005 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :* 1) CITY APPROVED PLAN TO BE ON SITE AT TIME OF INSPECTION. 2) 3005 INSTALLATION IS NOT PER YOUR UN APPROVED PLAN. 3) 3040 PIPING REQUIRES FITTINGS FOR CHANGE OF DIRECTION. 4) 3055 TEST W?? IS NOT INSTALLED CORRECTLY AND REQUIRE MINIMUN 1/4" PER FOOT ??? AT HCS CONNECTION TO TEST WYE. 5) PLEASE PIPING UNDER SLAB SHALL HAVE SEPARATION BETWEEN HOT & COLD TUBING. PLEASE HAVE PLUMBING CONTRACTOR ON SITE FOR INSPECTION. NOT A COMPLETE LIST.