Permit: T05CM02649

Parcel: 140383830

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/10/2005 FRAMING Approved IVRS - Inspection :*
10/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK ROOF SHEATHING AT HOOD VENT IN KITCHEN
2) PROTECT CONDUCTOR FROM TRUSS GANG PLATES OVER FRONT BEDROOM
10/03/2005 FRAMING Denied 1) BLOCK HVAC BOOT IN LAUNDRY 3 SIDES
2) BLOCK ROOF SHEATHING AT HOOD VENT IN KITCHEN
3) COMPLETE NAILS IN HOLDOWN S.W. CORNER
4) FIREBLOCK ENTRY
5) PROTECT CONDUCTOR FROM TRUSS GANG PLATES OVER MASTER ENTRY FRONT BED
6) NO DWV TEST
7) NAIL PROTECTION OVER WIRES BEDROOM/GARAGE WALL AND MASTER BATH