Permit: T05CM02631

Parcel: 140383400

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/12/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/10/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 1, 2, 3, 4 AND 5 OF 10/04/05 INSPECTION NOT DONE
2) NEXT FAILURE WILL RESULT IN REFEE
10/04/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP NON OVERLAPPING DBL TOP PLATES
2) CLIP GABLE ENDS TRUSS AT END PER 16/DT1
3) HEADERS MUST BEAR ON TRIMMERS
4) DIAGONAL BRACES REQUIRE TWO 16D NAILS EACH END
5) 7/DT1 OSB REQUIRES NAILS AT 6" ON CENTER ENDS AND EDGES
6) CLIP STUDS WITH HOLDOWNS FILL ALL NAIL HOLES IN SIMPSON HARDWARE
7) ROOF NOT NAILED