Permit: T05CM02599

Parcel: 110060760

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
01/25/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
05/16/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
UPC - PIPING INSTALLED IN A CONCRETE FOOTING SHALL BE SLEEVED OR INSTALLED IN RECESSED CHANNELS OR
I'M ONLY ASKING FOR FOAM WRAP
05/15/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
FOAM PIPE WRAP IS TO COVER ALL
PIPING IN CONCRETE
NOTE: CLOSET FLANGES ARE REQUIRED TO BE FASTENED TO FLOOR.
05/12/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE VACUUM BREAKERS ON CONSTRUCTION HOSE BIBS.
2. HAVE ALL PIPES WRAPPED AT PENETRATION THRU CONCRETE.
05/11/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
4" ABS BUILDING SEWER INSTALLED PER STAMPED PLAN.
CONNECTED TO EXISTING CLAY HCS. OK TO COVER.
2" SCH 40 PVC WATER LINE OK
2" SCH 40 PVC LANDSCAPING WATER PIPING INSTALLED.
NEW WATER METERS NOT YET INSTALLED.
CONNECTED TO 5/8" M.
PROVIDE CONTINUOUS SUPPORT UNDER PIPING
INSTALL VAC BREAKERS.
05/08/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
FROM BUILDINGS INTERIOR UNDERGROUND WATER TEST THRU 2-WAY CLEANOUTS TO 4" BUILDING SEWER APP. 40' FROM ROAD.
1. NEED TO VIEW PIPE WRAPS PRIOR TO CONCRETE.
2. HAVE APPROVAL STAMP ON SITE PLAN FOR SEWER.
03040-WATER PIPING TO BE INSTALLED PER PLAN OR PROVIDE REVISED APPROVED PLAN.
SITE PLAN TO HAVE PLAN CHECK APPROVAL STAMP.