Permit: T05CM02594

Parcel: 136141140

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02594

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/29/2005 FRAMING Approved IVRS - Inspection :*
11/28/2005 FRAMING Partial Approval IVRS - Inspection :*
1) FIREBLOCK TUB
2) OK TO INSULATE
11/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REINFORCE BENT STUDS BETWEEN KITCHEN AND BATH
2) INSTALL PLATE UNDER STAIRS SUPPORTS
3) SMOKE DETECTOR DOWNSTAIRS BEDROOM MUST BE AT LEAST 6" FROM CORNER
4) REWIRE RECEPTACLE S.W. BEDROOM
5) GROUT TUB
6) SUPPORT ABS EVERY 4 FEET
7) FIREBLOCK UNDER TUB
8) COMPLETE STUCCO LATHE