Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANGER REQUIRED WHERE GLU LAMS MEET IN 4R 2) B-3 TRUST INSTALLED BACKWARDS 3) GET ENGINEERING APPROVAL |