Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/26/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM #03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR R. CAMACHO 2) REINFORCE ALL WINDOWS AND DOORS 3) MISSING NAILS AT GARAGE JACK TRUSS HANGERS 4) FIREBLOCK GARAGE DROPPED CEILING NORTH WALL 5) FIREBLOCK LAUNDRY ROOM DROPPED CEILING 6) 50 POUNDS OF PRESSURE NEEDED AT PEX LINES NOT PRESSURIZED 7) DRYER VENT EXCEEDS 25' RUN 8) FIREBLOCK KITCHEN DROPPED CEILING 9) PLAN CALLS FOR 1 1/2" VTR AT KITCHEN SINK 10) PROVIDE 12" CLEARNCE WATER LINES FROM CANNS 11) SHIM ALL BEARING HEADERS 12) COMPLY WITH SHEARWALL (5) UPSTAIRS MASTER BEDROOM 13) FIRESTOP MECHANICAL CHASES UPSTAIRS 14) LOOSE STUD MASTER BATH VANITY WALL |